MIL-PRF-9954D
4.4.6 Sieve Analysis. For each representative sample, the sieve analysis shall be performed
on the sample obtained in Section 4.3 after it has been accurately reduced by riffle splitter (1:1
splitter). The samples to be taken are as follows: for MIL Size 3-7 approximately 100 grams,
MIL Size 8-10 approximately 50 grams, MIL Size 11-13 approximately 25 grams. The glass
beads shall conform to the size specification in MIL G-9954-A, Table 1. The size of the glass
beads shall be measured in accordance with ASTM D 1214 or any other generally accepted
mechanical or optical method that is just as accurate as ASTM D1214. Trace amounts (<0.4%)
round to zero.